Thermal Applications:
Defines a general method and criteria for measuring and ensuring that Micron components and modules do not exceed the maximum allowable temperature
|
TN-00-08
|
05/2010
|
252.18 KB
|
Technical Note
|
|
|
Moisture Absorption in Plastic Packages:
Describes shipping procedures for preventing memory devices from absorbing moisture and recommendations for baking devices exposed to excessive moisture
|
TN-00-01
|
02/2010
|
87.26 KB
|
Technical Note
|
|
|
The SMART Command Feature Set:
TN-FD-03: The SMART Command Feature Set
|
TN-FD-03
|
09/2010
|
485.87 KB
|
Technical Note
|
|
|
A Comparison of Client and Enterprise SSD Data Path Protection:
This technical marketing brief details and compares the key data path protection features that are designed into Micron’s RealSSD™ client and enterprise drives.
|
Technical Marketing Brief
|
11/2011
|
636.4 KB
|
Technical Marketing Brief
|
|
|
Media Management in Solid State Drives: Multistep WRITE Operations:
SSDs write data differently than conventional rotating hard drives (HDDs)—in a multistep process versus a single-step process. This brief examines the multistep write process for SSDs.
|
Technical Marketing Brief
|
04/2012
|
823.8 KB
|
Technical Marketing Brief
|
|
|
Best Practices for SSD Performance Measurement:
SSDs have pronounced write-history sensitivity, which means that they have unique requirements for accurately measuring their performance. This technical marketing brief documents how Micron measures enterprise SSD performance.
|
Technical Marketing Brief
|
01/2012
|
1.18 MB
|
Technical Marketing Brief
|
|
|
NAND Flash Media Management Through RAIN:
This brief describes the general concept of RAIN (redundant array of independent NAND) protection in enterprise solid state drives (SSDs) and details how this technology benefits Micron's RealSSD products.
|
Technical Marketing Brief
|
01/2012
|
541.38 KB
|
Technical Marketing Brief
|
|
|
An Overview of SSD Write Caching:
This brief provides an overview of the differences in SSD behavior when write cache is enabled versus disabled.
|
Technical Marketing Brief
|
05/2012
|
519.28 KB
|
Technical Marketing Brief
|
|
|
The SMART Command Feature Set for the RealSSD P400e Firmware 0135:
The intent of the SMART command feature set is to protect user data and minimize the likelihood of unscheduled system downtime that may be caused by predictable degradation and/or fault of the device.
|
TN-FD-05
|
01/2012
|
730.55 KB
|
Technical Note
|
|
|
The SMART Command Feature Set for the RealSSD™ P400e Firmware 0142:
The intent of the SMART command feature set is to protect user data and minimize the likelihood of unscheduled system downtime that may be caused by predictable degradation and/or fault of the device.
|
TN-FD-10
|
03/2012
|
740.86 KB
|
Technical Note
|